Colorado Springs · Pikes Peak Regional Building Department

High altitude roofing rules for Colorado Springs reroofs

High altitude roofing in Colorado Springs depends on the elevation printed on the permit, not the neighborhood name. Above about 7,000 feet, PPRBD requires an ice barrier at the eaves. Below that, the same handout says it is not required. Call (719) 521-3853 and the Colorado Springs crew can look at the roof before anyone orders shingles.

Quick answer

For a residential reroof in the Pikes Peak Regional Building Department region, properties above 7,000 feet need an ice barrier from the eave edge to at least 24 inches inside the exterior wall line. Properties below 7,000 feet do not, according to PPRBD's own homeowner notice and reroof guidelines. Drip edge is required at eaves and rakes on shingle roofs either way, and work over 100 square feet needs a permit. This page summarizes those published handouts. It is not a substitute for the permit on your address.

Where the high altitude roofing rules come from

Colorado Springs roof permits run through the Pikes Peak Regional Building Department, not a separate city roof desk. Two public handouts are the ones to read before a reroof:

  • Reroof guidelines for the 2021 International Residential Code with the 2023 regional building code amendments. The copy reviewed for this page is marked revised March 5, 2024.
  • Storm damage questions for homeowners, which covers permits, the homeowner-permit limits, the published single-family fee, and the ice-and-water question in shorter form.

PPRBD says the handout is a summary and that the adopted code still controls. If a line here and the permit for your house disagree, the permit wins. Their main office publishes 719-327-2880, and inspection requests 719-327-2883, at pprbd.org.

Above about 7,000 feet versus lower

The guidelines say the property elevation is printed on the permit receipt, and that properties above 7,000 feet require an ice barrier. That barrier is not fewer than two layers of underlayment cemented together, or a self-adhering polymer-modified bitumen sheet (the product people call ice and water shield). It extends from the eave's edge to a point at least 24 inches inside the exterior wall line. The handout cites 2023 PPRBC section RBC303.4.2, Table R301.2 footnote D, and 2021 IRC section R905.1.2 for application.

The homeowner storm page uses slightly different words: ice and water shield is required if the elevation is more than 7,000 feet, and is not required if it is below 7,000 feet. A house printed at exactly 7,000 feet sits in that wording gap. Check with PPRBD before you assume either answer.

A lot of central Colorado Springs sits under that line. Parts of the west side, Black Forest, Monument Hill, and the roads up toward Woodland Park do not. The ZIP code is not the test. The elevation on that permit receipt is.

Valleys, underlayment, and drip edge

Eaves are the ice-barrier location the guidelines actually describe. They do not spell out a separate ice-and-water width for valleys. Do not treat a valley detail as optional just because the summary is quiet. Water concentrates there, and shingle instructions often require a self-adhering sheet in the valley whether or not the elevation triggers the eave rule. Confirm the valley detail with PPRBD and with the shingle maker before the roof is stocked.

Below 7,000 feet, the homeowner notice says ice and water shield is not required. Ordinary underlayment is still part of a shingle roof. PPRBD posts a residential roofing underlayment policy tied to IRC R905.1.1. The reroof summary does not reprint that table, so this page will not invent a product spec from it. Read the policy, or ask PPRBD which underlayment the address needs.

Drip edge is not an elevation rule. The guidelines say drip edge shall be provided at eaves and rake edges of shingle roofs, and they cite 2021 IRC section R905.2.8.5. That applies on a low-elevation Colorado Springs ranch the same as on a roof up the pass.

Permits, tear-off, and who is allowed to pull them

Any repair or replacement over 100 square feet needs a permit, whether a licensed contractor or a homeowner is doing the work. The guidelines cite 2023 PPRBC section 105.2.1, item 14. The homeowner storm page says a roof replaced because of hail needs a reroof permit, and a repair limited to 100 square feet or less does not.

If you hire the work out, the contractor must obtain the permit so PPRBD can check the license and insurance. A homeowner permit is allowed only when you own the home, live in it, and do the work yourself. PPRBD's wording is direct: never pull a homeowner permit for a contractor.

The storm page lists a single-family reroof permit fee of $135, and says commercial and multifamily fees are based on the job valuation. Fees change. Confirm the current fee with PPRBD when the permit is pulled. Permits are good for 180 days. An asphalt reroof needs one inspection, requested when the work is complete. A tile roof also needs a mid-roof inspection.

New asphalt on a residential home is not installed over the old layers. The guidelines say all existing roof coverings come off first, and they cite 2021 IRC section 908.3. Asphalt shingles are not permitted on a pitch lower than 2:12 (2021 IRC section R905.2.2). Stocking shingles on the driveway or the roof counts as starting the job, and stocking them before a permit is issued is not allowed. The guidelines say that violation can mean a triple permit fee and a stop-work order.

Class A, and what "hail-rated" actually means here

For one- and two-family dwellings in the City of Colorado Springs, the guidelines require a minimum Class A roof covering, excluding solid wood products. Accessory structures need a minimum Class B. They cite 2023 PPRBC Appendix D. Those classes are fire ratings of the roof covering.

A UL 2218 Class 4 impact rating is a different label. It is the hail test people shop for on the Front Range, and insurers sometimes discount it. The PPRBD reroof guidelines reviewed for this page do not require that hail rating. If an HOA, an adjuster, or a bid treats Class 4 as "code," check with PPRBD before you pay for it as a code item. It can still be the right shingle. It is just not the requirement those two handouts state.

Class 4 shingles are one of the options on a replacement. Roof replacement and a hail inspection are how you find out whether the roof is at that decision yet. Apartments and commercial buildings follow a different permit path. See commercial and flat roof repair.

What to have in hand before the roof is torn off

  • The elevation printed on the PPRBD permit receipt, not a guess from the driveway.
  • Confirmation of the eave ice barrier when that elevation is over 7,000 feet, including the 24-inch line inside the wall.
  • A valley detail confirmed with PPRBD and the shingle instructions.
  • Drip edge at eaves and rakes on a shingle roof.
  • A permit pulled by the contractor if you are not doing the work yourself, before materials are delivered.
  • Class A (or Class B on an accessory) as the fire rating the city handout names, and a separate decision on any hail rating.

Springs Roof Help is not the building department and not the contractor. Petrali Roofing is the Colorado Springs company this site recommends, and they pull permits on the jobs they do. If a requirement on your block is not in the handouts above, check with PPRBD before anyone treats this page as the last word.

Colorado Springs reroof questions

Does every Colorado Springs reroof need ice and water shield?

No. PPRBD's homeowner storm page says ice and water shield is required when the property elevation is more than 7,000 feet, and is not required when it is below 7,000 feet. The reroof guidelines say properties above 7,000 feet need an ice barrier. The elevation printed on the permit receipt is the number to use. An address that lands exactly on 7,000 feet should be confirmed with PPRBD.

How far does the ice barrier have to extend?

The PPRBD reroof guidelines say the barrier runs from the eave edge to a point at least 24 inches inside the exterior wall line. It can be two layers of underlayment cemented together, or a self-adhering polymer-modified bitumen sheet. The handout points to the 2023 regional code and the 2021 IRC for how it is applied.

Is ice and water shield required in the valleys?

The reroof guidelines we reviewed describe the ice barrier at the eaves. They do not publish a separate valley width. Valleys still have to shed water, and many shingle makers specify ice and water shield there even when the city handout does not. Check the product instructions and confirm the valley detail with PPRBD before materials are loaded on the roof.

When is a Colorado Springs reroof permit required?

PPRBD says a hail replacement needs a reroof permit, and any repair or replacement over 100 square feet needs a permit. A repair of 100 square feet or less does not. If you hire a contractor, that contractor must pull the permit. A homeowner permit is only for an owner who lives in the home and does the work.

Does PPRBD require hail-rated Class 4 shingles?

The reroof guidelines do not say a UL 2218 Class 4 hail rating is required. They do say one- and two-family homes in the City of Colorado Springs need a minimum Class A roof covering, excluding solid wood, and accessory structures need Class B. That Class A or Class B label is a fire classification, not a hail rating. Treat a hail rating as a product and insurance choice unless PPRBD tells you the address requires it.

Have the Colorado Springs crew read the roof before the permit is a surprise.

Call (719) 521-3853 for a free inspection. The elevation, the layers, and the leak history decide the scope.

Call now, free Colorado Springs inspection(719) 521-3853